The FLIR TG267 takes you beyond the limitations of single-spot IR thermometers to both see and evaluate the hot and cold spots that can indicate serious issues. Ideal for commercial electrical, facility maintenance, and HVAC applications, this advanced thermal camera with a brilliant 2.4 inch screen reduces diagnostic time while simplifying repair and maintenance reporting. Patented FLIR MSX? (Multi-Spectral Dynamic Imaging) enhancement improves image clarity by embossing visual scene details on full thermal images, providing added context to help you accurately target potential faults and troubleshoot repairs. Record images to monitor maintenance history and reassure your customer that problems have been resolved.

Qty:
Compare

Description

IR Resolution
160 × 120 pixels
Thermal Sensitivity/NETD
<70 mK
Accuracy
±1.5°C (2.7°F) for temperatures 50°C to 100°C (122°F to 212°F); up to ±3°C (±5.4°F) for -25°C to 50°C (-13°F to 122°F) and 100°C to 380°C (212°F to 716°F)
Field of view (FOV)
57° × 44°
Image Modes
• MSX® (Multi Spectral Dynamic Imaging) • Visual with temperature reading
Display
320 × 240 pixel, 2.4 in color LCD
Storage Media
eMMC 4 GB
Imaging & Optical
Built-in Digital Camera
Yes
Color Palettes
Iron, Rainbow, White hot, Black hot, Arctic, Lava
Detector Pitch
12 µm
Detector Type
Focal plane array (FPA), uncooled microbolometer
Digital image enhancement
Yes
Field of view (FOV)
57° × 44°
Focus
Focus free
Gallery
Yes
Image Frequency
8.7 Hz
Image Modes
• MSX® (Multi Spectral Dynamic Imaging) • Visual with temperature reading
IR Resolution
160 × 120 pixels
Laser
Class 1 laser indicates the temperature measurement area; button-activated
Minimum Focus Distance
0.3 m (0.98 ft)
Minimum Measurement Distance
0.26 m (0.85 ft)
Spectral Range
7.5 – 14 µm
Thermal Sensitivity/NETD
<70 mK
Measurement & Analysis
Accuracy
±1.5°C (2.7°F) for temperatures 50°C to 100°C (122°F to 212°F); up to ±3°C (±5.4°F) for -25°C to 50°C (-13°F to 122°F) and 100°C to 380°C (212°F to 716°F)
Camera size (L x W x H)
210 × 64 × 81 mm (8.3 × 2.5 × 3.2 in)
Camera weight incl battery
0.394 kg (13.9 oz)
Center spot
Yes
Emissivity Correction
Yes: 4 preset levels with custom adjustment of 0.1–0.99
Object Temperature Range
-25°C to 380°C (-13°F to 716°F)
Set-up Commands
• Local adaptation of units, language, date, and time formats • Screen brightness (high, medium, low) • Gallery, deletion of images
Spot Meter
Center spot on/off
User Interface
Display
320 × 240 pixel, 2.4 in color LCD
Languages
Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, simplified Chinese, Spanish, Swedish, traditional Chinese, Turkish.
Power
Battery charge life
30 days minimum
Battery operating time
5 hours continuous scanning, 4.5 hours with laser on
Battery type
Rechargeable Li ion battery
Battery voltage
3.7 V
Charging system
Battery is charged inside the camera
Charging Temperature
0°C to 45°C (32°F to 113°F)
Charging Time
4 hours to 90%, 6 hours to 100%
Power Management
Adjustable: off, 5 min., 15 min., 30 min.
Environmental & Certifications
Drop test
Designed for 2 m (6.6 ft)
EMC
• EN 61000-6-3 • EN 61000-6-2 • FCC 47 CFR Part 15 Class B
Encapsulation
IP 54 (IEC60529)
Humidity (Operating and Storage)
0-90% RH (0-37°C (32-98.6°F)), 0-65% RH (37-45°C (98.6-113°F)), 0-45% RH (45-55°C (113-131°F))
Operating Temperature Range
-10°C to 45°C (14°F to 113°F)
Radio Spectrum
• ETSI EN 300 328 • FCC Part 15.249 • RSS-247 Issue 2 • EN 301 489-1:2011 • EN 301 489-17:2009
Safety
CE/CB/EN61010/UL
Shock
25 g (IEC 60068-2-27)
Storage Temperature Range
-30°C to 55°C (-22°F to 131°F)
Tripod Mounting
1/4 in.-20 on handle bottom
Vibration
2 g (IEC 60068-2-6)
Warranty
FLIR 2-10 warranty
General
Includes
TG267, printed documentation, wrist strap lanyard, USB A to USB C cable, carry pouch