FLIR DM286

100,831.00 GST Extra

The FLIR DM286 industrial imaging multimeter is the ultimate tool for electrical inspectors seeking a safe, accurate, and efficient way to identify, document, and share findings. With IGM™ (Infrared Guided Measurement) and MSX® (Multi-Spectral Dynamic Imaging), you can safely identify where hazards might be before contact is ever made. The powerful multimeter can capture and store up to 30,000 images and 100 log files, with the ability to record thermal and visual video clips. Stream live data in real time from the DM286 to your mobile device. Use the METERLiNK® app to quickly and efficiently capture readings, images, and videos for analysis, trending, and sharing.

Qty:
Compare
Categories: ,

Description

IR Resolution
160 × 120 (19,200 pixels)
Display Counts
6000
AC/DC Voltage
1000 V AC RMS ±(1.0%+3) 1000 V DC ±(0.09%+3)
AC/DC Amps
10.00 A AC RMS ±(1.5%+3) 10.00 A DC ±(1.0%+3)
Connectivity
Bluetooth BLE
IMAGING & OPTICAL
Color Palettes
Iron, rainbow, arctic, white hot, and black hot
Field of view – visual
71° × 56°
Focus
Fixed
Frame Rate
9 Hz
Image Modes
Thermal MSX (Multi Spectral Dynamic Imaging)
Thermal Camera only
Digital Camera only
IR Resolution
160 × 120 (19,200 pixels)
IR Sensitivity
150 mK (0.15°C)
Spectral Response
8–14 µm
Thermal Imaging Detector
FLIR Lepton® microbolometer
Visual Focus and FOV
Fixed focus, 71° × 56° FOV
Visual Resolution
2 MP (1600 × 1200 pixels)
MEASUREMENT & ANALYSIS
AC/DC Amps
10.00 A AC RMS ±(1.5%+3) 10.00 A DC ±(1.0%+3)
AC/DC LoZ V
1000 V AC RMS or 1000 V DC ±(1.3%+4)
AC/DC mVolt
AC 600.0 mV ±(1.0%+3) DC 600.0 mV±(0.2%+3)
AC/DC Voltage
1000 V AC RMS ±(1.0%+3) 1000 V DC ±(0.09%+3)
Calibration Cycle
Once per year, recommended
Capacitance
10.00 mF ±(4.0%+5)
Continuity check threshold
10–100Ω
Diode Test
1.500 V ± 0.9%
Display Counts
6000
Frequency Counter
100.00 kHz ±(0.1%+5)
Measuring Rate
3 samples per second
Resistance
6.000 MΩ ±(0.9%+5), 60.00 MΩ ±(3.0%+5)
Temperature Accuracy
±3°C (5.4°F) or ± 3% of the reading (whichever is greater) for temperatures > 25°C (77°F) ±5°C for temperatures -10°C to 25°C (14°F to 77°F)
Temperature Range
–5°C to 300°C (23°F to 572°F)
Temperature Resolution
0.1°C (0.1°F)
Temperature Type K thermocouple
-40°C to 400°C DMM ± (1.0% + 3°C) / IGM ± (1.0% + 5°C)
(-40°F to 752°F DMM ± (1.0% + 5.4°F) / IGM ± (1.0% + 9°F)
Thermal Sensitivity
150 mK (0.15°C)
VFD
AC V: 1000 V AC RMS, ±(1.3%+4) at 45∽65 Hz
COMMUNICATION & DATA STORAGE
Communication Protocol
METERLiNK
Connectivity
Bluetooth BLE
Image File Format
Radiometric
Storage
40,000 readings per memory set
Storage Media
eMMC 4GB
Stored Image Capacity
up to 30,000
Video Recording
50 minutes maximum duration
20 seconds max duration for file transmission
USER INTERFACE
Display
2.8″
Display Brightness
High, Medium, Low
POWER
Auto Power Off
For Meter: set to OFF, 2, 5, or 10 minutes
For Worklight only: set to OFF, 5, 15, or 30 minutes
Battery
TA04, Lithium Polymer Rechargeable, 3050 mAh. Two supplied.
Battery life
Approx. 6.5 hours in IGM mode with display brightness set to medium.
Approx. 10 hours in Multimeter mode (medium brightness)
Non_Contact Voltage Detector [NCV]
Yes
GENERAL
Dimensions (L x W x H)
20 cm × 9.6 cm × 5.6 cm (7.9 in × 3.8 in × 2.2 in)
Included
1 x DM286 Industrial Thermal Imaging Multimeter
1 set of CATIV 600V Test Lead
1 set of CATIV 600V Alligator Clip
1 x Type-A to Micro-USB Cable (with Data transfer capability)
1 x K-type Thermocouple (-30°C to 260°C)
1 x Soft-sided carrying case
1 x FLIR Quick Start Guide
1 x FLIR Warranty Card
2 x TA04 Rechargeable Battery Cell
Scanning Mode
Continuous scan. Crosshairs and laser pointer targeting.
Weight
569 g (1.25 lb) without battery (approx.)
Worklights
x1 LED
ENVIRONMENTAL & CERTIFICATIONS
Certifications
ETL, FCC, CE, RCM, UKCA, FDA, EN60825, EN50689
Drop test
2 m (6.6 ft)
EMC
EN61326-1
Emissivity Settings
0.10 to 1.00 (default is 0.95); select from four presets or set manually.
IP Rating
IP40
Laser Pointer Power
≤0.39 mW
Laser Type
Class I (red)
Laser Wavelength
640 nm to 660 nm
Operating Altitude
2000 m (6560 ft)
Operating Temp & Humidity
-10°C to 30°C (14°F to 86°F), <85% RH
30°C to 40°C (86°F to 104°F), <75% RH
40°C to 50°C (104°F to 122°F), <45% RH
Pollution Degree
2.0
Safety
IEC 61010-1 CAT IV – 600 V, CAT III – 1000 V
Storage temperature and relative humidity [RH]
-20°C to 60°C (-4°F to 140°F), 0–80% RH (without batteries)
Warranty
Limited 10-Year Warranty https://www.flir.com/testwarranty
ACCESSORIES
Software
FLIR METERLiNK® app