Description
Specifications
- Digital I/O connector type
- M12 12-pin A-coded, Male (shared with external power)
- Digital Inputs
- 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
- Digital Output Purpose
- • As a function of alarm, output to external device • Fault (NC)
- Digital Outputs
- 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
- Encoding
- Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS, FLIR radiometric
- Ethernet Interface
- Wired, Wi-Fi (optional)
- WiFi
- Optional feature purchased separately. RP-SMA, female connector
- EMC
- • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC – Earth-moving and building construction machinery) • EN ISO 14982 (EMC – Agricultural and forestry machinery)
- Image Fequency
- 30 Hz
- Thermal Sensitivity/NETD
- Lens dependent
- Accuracy
- ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
- Alarm Functions
- On any selected measurement function; digital in; internal camera temperature
- Alarm Output
- • Digital out • E-mail (SMTP) (push) • EtherNet/IP (pull) • File transfer (FTP) (push) • Modbus TCP master write (push) • Modbus TCP slave (pull) • MQTT (push) • Query over RESTful API (pull) • ONVIF • Store image or video
Communication & Data Storage
- Digital I/O connector type
- M12 12-pin A-coded, Male (shared with external power)
- Digital I/O isolation voltage
- 500 VRMS
- Digital input purpose
- NUC, NUC disable, alarm
- Digital Inputs
- 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
- Digital Output Purpose
- • As a function of alarm, output to external device • Fault (NC)
- Digital Outputs
- 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
- Encoding
- Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS, FLIR radiometric
- Ethernet
- For control, result, image, and power
- Ethernet Communication
- TCP/IP socket-based FLIR proprietary
- Ethernet Connector Type
- M12 8-pin X-coded, female; RP-SMA, female
- Ethernet Interface
- Wired, Wi-Fi (optional)
- Ethernet Power
- Power over Ethernet, PoE IEEE 802.3af class 3
- Ethernet Protocols
- • EtherNet/IP • IEEE 1588 • Modbus TCP Master • Modbus TCP Slave • MQTT • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP
- Ethernet Standard
- IEEE 802.3
- Ethernet Type
- 1000 Mbps
- Image Storage
- Records up to 100 FLIR radiometric JPEG; storage as function of: alarm, scheduling, or user interaction (camera web)
- Multicast
- Yes
- RS-232
- M8 A-coded, male connector
- Video Storage
- Records up to 10 H.264 videos; storage as function of alarm — 5 sec. before alarm and 5 sec. after alarm.
- WiFi
- Optional feature purchased separately. RP-SMA, female connector
Imaging & Optical
- Available Lenses
- 6°, 24°, 14°, 42°, 2.0x Micro, Dual FOV (14° + 24°) athermalized lenses, 80°
- Contrast Enhancement
- FSX® / Histogram equalization (IR only)
- Detector Pitch
- 12 µm
- Focal Plane Array (FPA)
- Uncooled microbolometer
- Focus
- One-shot contrast, motorized, and manual
- Image Fequency
- 30 Hz
- Image Source
- Video stream 0: visual / IR / MSX® (visual camera is an optional feature) Video stream 1: visual Radiometric video stream: IR
- IR Resolution
- 640 × 480
- Multi-Streaming
- Yes
- Overlay
- With / Without
- Pixel Format
- Video stream: YUV411 Radiometric stream: MONO 16
- Radiometric IR video streaming
- RTSP protocol
- Readout
- Measurement results: • Ethernet/IP (pull) • Modbus TCP master (push) • Modbus TCP slave (pull) • MQTT (push) • Query over REST API (pull) • Measurements and still image (radiometric JPEG, visual 640 × 480, visual 1280 × 960), read access only • Web interface
- Spectral Range
- 7.5–14 µm
- Streaming Resolution
- Video stream 0: 640 × 480 pixels Video stream 1: 1280 × 960 pixels Radiometric stream: 320 × 240 pixels
- Thermal Sensitivity/NETD
- Lens dependent
- Video Streaming
- RTSP protocol
- Visible Camera
- Optional accessory; disabled when 80° lens in use
Measurement & Analysis
- Accuracy
- ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
- Alarm Functions
- On any selected measurement function; digital in; internal camera temperature
- Alarm Output
- • Digital out • E-mail (SMTP) (push) • EtherNet/IP (pull) • File transfer (FTP) (push) • Modbus TCP master write (push) • Modbus TCP slave (pull) • MQTT (push) • Query over RESTful API (pull) • ONVIF • Store image or video
- Atmospheric transmission correction
- Based on inputs of distance, atmospheric temperature, and relative humidity
- Automatic hot & cold detection
- Max./min. temperature value and position shown within box
- Measurement Corrections
- Global object parameters; local parameters per analyze function
- Measurement Presets
- Yes
- Measurement Tools
- 10 spotmeters, 10 boxes or mask polygons, 3 Deltas (difference any value/reference/external lock), 2 isotherms (above/below/interval), 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline
- Object Temperature Range
- -20°C to 120°C (-4°F to 248°F), 0°C to 650°C (32°F to 1202°F), 300°C to 2000°C (572°F to 3632°F)
General
- Base Mounting
- 4× M4 on 4 sides
- Housing material
- Aluminium
- Size (L x W x H)
- 123 × 77 × 77 mm (4.84 × 3.03 × 3.03 in)
- Weight
- 0.82 kg (1.8 lb), camera only
Environmental & Certifications
- Corrosion
- • ISO 12944 C4 G or H • EN60068-2-11
- EMC
- • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC – Earth-moving and building construction machinery) • EN ISO 14982 (EMC – Agricultural and forestry machinery)
- Encapsulation
- IEC 60529, IP 54, IP66 with accessory
- Humidity (Operating and Storage)
- IEC 60068-2-30/24 hours, 95% relative humidity, 25°C–40°C (77°F–104°F)/2 cycles
- ONVIF Conformance
- Yes. ONVIF Profile S
- Operating Temperature Range
- -20°C to 50°C (–4°F to 122°F): • -20°C to 40°C (-4°F to 104°F) (in free air) • 40°C to 50°C (104°F to 122°F) (mounted on cooling plate accessory) Maximum camera case temperature: 65°C (149°F)
- Radio Spectrum
- • FCC 47 CFR Part 15 Class C (2.4 GHz band US) • FCC 47 CFR Part 15 Class E (5 GHz band US) • RSS-247 (2.4 GHz and 5 GHz band Canada) • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU) • ETSI EN 301 893 V2.1.1 (5 GHz band EU)
- Shock
- IEC 60068-2-27, 25 g
- Tripod Mounting
- UNC ¼″-20 on 2 sides
- Vibration
- • IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal • IEC 61373 Cat 1 (Railway)
Power
- External Power Operation
- 24/48 V DC 8 W max
- External Voltage
- Allowed range 18–56 V DC
- Power Connection
- M12 12-pin A-coded, male (shared with Digital I/O)
- Power Consumption
- • 7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical
User Interface
- Web interface
- Yes