FLIR A65 | Vamara Techware

FLIR A65

FLIR A65 is a thermal imaging temperature sensor for process control/quality assurance, fire prevention, and condition monitoring that offers comprehensive visual temperature monitoring. The A65 integrates seamlessly into existing systems and provides temperature linear output through GenICam? compliant software.

Qty:
View Your Request For Quote
Compare

Description

FLIR?A65 FOV 25 (30 Hz, ver. 2016).
SPECIFICATIONS
GENERAL
Package Includes
Cardboard box, thermal imaging camera with lens, focus adjustment tool, printed documentation, user documentation CD-ROM, FLIR Tools download card
OVERVIEW
Base Mounting
4 ? M3 thread mounting holes (bottom)
Camera size (L x W x H)
107.8 ? 49.6 ? 46.6 mm (4.2 ? 1.9 ? 1.8 in.)
Detector Type
Focal plane array (FPA), uncooled VOX microbolometer
FLIR Screen-EST Mode
No
Housing material
Magnesium and aluminum
Weight
0.21 kg (0.46 lb.)
CONNECTIONS & COMMUNICATIONS
Digital I/O connector type
12-pole M12 connector (shared with Digital Synchronization and External power)
Digital I/O isolation voltage
500 VRMS
Digital I/O supply voltage
2?40 VDC, max 200 mA
Digital input purpose
General Purpose
Digital Inputs
1? opto-isolated, “0” <1.2 VDC, “1” = 2?25 VDC.
Digital Output Purpose
General purpose output to ext. device (programmatically set)
Digital Outputs
1? opto-isolated, 2?40 VDC, max 185 mA
Digital Synchronization Connector Type
12-pole M12 connector (shared with Digital I/O and External power)
Ethernet
Control and image
Ethernet Communication
GigE Vision ver. 1.2 Client API GenICam compliant
Ethernet Connector Type
RJ-45
Ethernet Image Streaming
8-bit monochrome @ 30 Hz Signal linear/ DDE Automatic/ Manual Flip H&V 14-bit 640 ? 512 pixels @ 30 Hz Signal linear/ DDE Temperature linear GigE Vision and GenICam compatible
Ethernet Power
Power over Ethernet, PoE IEEE 802.3af class 0 Power
Ethernet Protocols
TCP, UDP, ICMP, IGMP, DHCP, GigEVision
Ethernet Standard
IEEE 802.3 / RJ-45
Ethernet Type
Gigabit Ethernet
Synchronization in
1?, non-isolated
Synchronization in – purpose
Frame sync in to control camera
Synchronization in – type
LVC Buffer @3.3V, “0” <0.8 V, “1” >2.0 V.
Synchronization out
1?, non-isolated
Synchronization out – purpose
Frame sync out to control another Ax5 camera
Synchronization Out – type
LVC Buffer @ 3.3V, “0”=24 MA max, “1”= ?24 mA max.
ENVIRONMENTAL
Atmospheric transmission correction
Automatic, based on inputs for distance, atmospheric temperature and relative humidity
EMC
EN 61000-6-2 (Immunity) EN 61000-6-3 (Emission) FCC 47 CFR Part 15 Class B (Emission)
Emissivity Correction
Variable from 0.5 to 1.0
Encapsulation
IP 40 (IEC 60529) with base support mounted
Humidity (Operating and Storage)
IEC 60068-2-30/24 h 95% relative humidity 25?C to 40?C (77?F to 104?F)
Operating Temperature Range
?15?C to 50?C (5?F to 122?F) The operating temperature range assumes that the camera is mounted on the base support (included in the package) or a similar type of heatsink.
Shock
25 g (IEC 60068-2-27)
Storage Temperature Range
?40?C to 70?C (?40?F to 158?F)
Tripod Mounting
UNC ?”-20 (on three sides)
Vibration
2 g (IEC 60068-2-6 & MIL-STD810G)
IMAGING & OPTICAL
Detector Pitch
17 ?m
Detector Time Constant
Typical 12 ms
Field of view (FOV)
25? ? 20? with 25 mm lens
f-number
1.25
Focal Length
25 mm (0.98 in.)
Focus
Fixed
Image Frequency
30 Hz
IR Resolution
640 ? 512 pixels
Spatial resolution (IFOV)
0.68 mrad
Spectral Range
7.5?13 ?m
Thermal Sensitivity/NETD
<0.05?C @ 30?C (86?F) / 50 mK
MEASUREMENT & ANALYSIS
Accuracy
?5?C (?9?F) or ?5% of reading
External Optics & Windows Correction
Automatic, based on input of optics/window transmission and temperature
Measurement Corrections
Global object parameters
Object Temperature Range
-25?C to 135?C (-13 to 275?F) / ?40?C to 550?C (-40 to 1022?F)
Optics Transmission Correction
Automatic, based on signals from internal sensors
Reflected apparent temperature correction
Automatic, based on input of reflected temperature
POWER
External Power Connector Type
12-pole M12 connector (shared with Digital I/O and Digital Synchronization )
External Power Operation
12/24 VDC, < 3.5 W nominal < 6.0 W absolute max
Voltage
Allowed range 10?30 VDC

Reviews

There are no reviews yet.

Be the first to review “FLIR A65”

Your email address will not be published. Required fields are marked *