Description
Specifications
- Digital I/O connector type
- M12 12-pin A-coded, Male (shared with external power)
- Digital Inputs
- 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
- Digital Output Purpose
- Programmatically set; fault (NC)
- Digital Outputs
- 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
- Encoding
- RTSP video streaming: H.264 / MPEG4 / MJPEG RTSP radiometric streaming: compressed JPEG-LS, FLIR radiometric GVSP video streaming: uncompressed GVSP radiometric streaming: temperature linear and FLIR radiometric
- Ethernet Interface
- Wired, Wi-Fi (optional)
- WiFi
- Optional feature purchased separately. RP-SMA, female connector
- EMC
- • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC – Earth-moving and building construction machinery) • EN ISO 14982 (EMC – Agricultural and forestry machinery)
- f-number
- 1.4
- Image Fequency
- 30 Hz
- Thermal Sensitivity/NETD
- <35 mK
- Accuracy
- ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
- Alarm Functions
- NA
- Alarm Output
- NA
Communication & Data Storage
- Digital I/O connector type
- M12 12-pin A-coded, Male (shared with external power)
- Digital I/O isolation voltage
- 500 VRMS
- Digital input purpose
- NUC; NUC disable; image TAG (Start, Stop, General); image flow control (acc. SFNC 2.3): • Single frame (on trigg) • Multiframe (on trigg) • Continuous
- Digital Inputs
- 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
- Digital Output Purpose
- Programmatically set; fault (NC)
- Digital Outputs
- 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
- Encoding
- RTSP video streaming: H.264 / MPEG4 / MJPEG RTSP radiometric streaming: compressed JPEG-LS, FLIR radiometric GVSP video streaming: uncompressed GVSP radiometric streaming: temperature linear and FLIR radiometric
- Ethernet
- For control, result, image, and power
- Ethernet Communication
- • GigE Vision ver. 1.2 • Client API GenICam compliant • TCP/IP socket-based FLIR proprietary
- Ethernet Connector Type
- M12 8-pin X-coded, female; RP-SMA, female
- Ethernet Interface
- Wired, Wi-Fi (optional)
- Ethernet Power
- Power over Ethernet, PoE IEEE 802.3af class 3
- Ethernet Protocols
- • IEEE 1588 • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP, GVSP, GVCP
- Ethernet Standard
- IEEE 802.3
- Ethernet Type
- 1000 Mbps
- Image Storage
- NA
- Multicast
- Yes
- ONVIF Profile S Compliant
- Yes
- RS-232
- M8 A-coded, male connector
- Serial Communication
- Pan & Tilt control. Pelco D standard HW interface: RS232 and RS485 exclusively
- WiFi
- Optional feature purchased separately. RP-SMA, female connector
Imaging & Optical
- Contrast Enhancement
- FSX® / Histogram equalization (IR only)
- Detector Pitch
- 17 µm
- Field of view (FOV)
- 29° × 22°
- f-number
- 1.4
- Focal Length
- 14.3 mm (0.56 in)
- Focal Plane Array (FPA)
- Uncooled microbolometer
- Focus
- Fixed, adjustable with included tool
- Image Fequency
- 30 Hz
- IR Resolution
- 464 × 348
- Minimum Focus Distance
- 0.25 m (0.82 ft)
- MSX
- Yes, included in visual camera option
- Overlay
- Without
- Radiometric IR video streaming
- GigE Vision and RTSP
- Readout
- No measurements readouts, only streamed video
- Spectral Range
- 7.5–14 µm
- Streaming Resolution
- RTSP video streaming, source 0: 640 × 480 pixels RTSP video streaming, source 1: 1280 × 960 pixels RTSP radiometric streaming: 464 × 348 pixels GVSP video streaming: 640 × 480 pixels GVSP radiometric streaming: 464 × 348 pixels
- Thermal Sensitivity/NETD
- <35 mK
- Video Streaming
- RTSP or GVSP (GigE Vision) protocols
- Visible Camera
- Optional accessory
Measurement & Analysis
- Accuracy
- ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
- Alarm Functions
- NA
- Alarm Output
- NA
- Atmospheric transmission correction
- Based on inputs of distance, atmospheric temperature, and relative humidity
- Automatic hot & cold detection
- NA
- Measurement Corrections
- NA
- Measurement Presets
- NA
- Measurement Tools
- NA
- Object Temperature Range
- –20 to 175°C (–4 to 347°F) 175 to 1000°C (347 to 1832°F)
General
- Base Mounting
- 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate
- Housing material
- Aluminium
- Size (L x W x H)
- 107 × 67 × 57 mm (4.21 × 2.64 × 2.24 in)
- Weight
- 519g (1.14lb) without bottom cooling plate
Environmental & Certifications
- Corrosion
- • ISO 12944 C4 G or H • EN60068-2-11
- EMC
- • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC – Earth-moving and building construction machinery) • EN ISO 14982 (EMC – Agricultural and forestry machinery)
- Encapsulation
- IEC 60529 and IP66
- Humidity (Operating and Storage)
- IEC 60068-2-30/24 hours, 95% relative humidity, 25–40°C (77–104°F)/2 cycles EN60068-2-38
- Operating Temperature Range
- –20 to 50°C (–4 to 122°F) Bottom cooling plate is needed in temperatures above 40°C (104°F). Maximum internal temperature sensor: 70°C (158°F)
- Radio Spectrum
- • FCC 47 CFR Part 15 Class C (2.4 GHz band US) • FCC 47 CFR Part 15 Class E (5 GHz band US) • RSS-247 (2.4 GHz and 5 GHz band Canada) • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU) • ETSI EN 301 893 V2.1.1 (5 GHz band EU)
- Shock
- IEC 60068-2-27, 25 g
- Tripod Mounting
- 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate
- Vibration
- • IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal • IEC 61373 Cat 1 (Railway)
Power
- External Power Operation
- 24/48 V DC 8 W max
- External Voltage
- Allowed range 18–56 V DC
- Power Connection
- M12 12-pin A-coded, male (shared with Digital I/O)
- Power Consumption
- • 7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical
User Interface
- Web interface
- Yes